Non-Contact Liquid Level Sensor Stick Type Water Detector Switch DC XKC-Y25-NPN
The XKC-Y25-NPN is a non-contact liquid level sensor designed for detecting water or other liquids in various industrial and commercial applications. It operates based on the principle of capacitance or electrical field sensing, providing reliable detection without physical contact with the liquid. This makes it ideal for applications where the liquid needs to be monitored without the sensor coming into direct contact with the liquid, preventing wear, corrosion, or contamination. It is commonly used for water level detection, overflow prevention, and dry-run protection in tanks, reservoirs, and other fluid systems.
Product Details:
Model: XKC-Y25-NPN Non-Contact Liquid Level Sensor Switch
Sensor Type: Non-Contact Capacitive
Detection Object: Water / Liquid
Detection Range: 0.5 cm to 5 cm (depending on the liquid type and surface)
Output Type: NPN Output (Sinking Type)
Power Supply: DC 6V to 36V
Response Time: < 10 ms
Detection Method: Capacitance-based sensing
Sensing Mode: Stick Type (Flexible installation along the tank or surface)
Mounting Type: Stick-style / Surface-mountable
Operating Temperature Range: -20°C to +60°C
Protection Rating: IP67 (Dust-tight and waterproof)
Size: Stick-type design (Length: 250mm, Diameter: 12mm)
Weight: Approx. 50g
Cable Length: 2 meters
Key Features:
-
Non-Contact Detection:
The XKC-Y25-NPN uses capacitive sensing technology to detect the presence of liquids without any physical contact with the fluid. This non-contact method reduces wear and tear, prevents contamination, and extends the sensor's lifespan. -
High Sensitivity:
This sensor is sensitive enough to detect liquid levels as low as 0.5 cm, allowing for precise control of liquid levels in tanks or reservoirs. -
Fast Response Time:
With a response time of less than 10 ms, the sensor provides instantaneous feedback, making it suitable for high-speed applications where timely detection is essential. -
NPN Output:
The sensor provides an NPN output, a sinking signal type, which is ideal for controlling processes such as switching pumps, alarms, or actuators. The NPN output is commonly used in systems that require an active low signal for triggering actions. -
Waterproof and Durable:
The IP67 rating ensures the sensor is dust-tight and waterproof, making it suitable for outdoor or harsh industrial environments where exposure to moisture and dirt is common. -
Flexible Mounting:
The stick-type design allows the sensor to be easily mounted in various configurations along the surface of a tank or reservoir. The compact size (250mm length, 12mm diameter) ensures it fits into tight spaces. -
Wide Voltage Range:
The sensor operates within a wide DC voltage range (6V to 36V), making it compatible with most industrial control systems and easily integrated into a variety of applications. -
Long-Lasting Performance:
The XKC-Y25-NPN is built for longevity, ensuring a long service life without the need for frequent maintenance or replacement, even in challenging conditions.
How to Use the XKC-Y25-NPN Non-Contact Liquid Level Sensor:
1. Mounting the Sensor:
-
Mounting Position:
The XKC-Y25-NPN can be mounted on the surface of the liquid tank or reservoir. Its stick-type design allows easy positioning at various heights to monitor specific liquid levels, such as minimum or maximum levels.-
Place the sensor vertically or horizontally along the side of the tank, ensuring the sensing area is in contact with the liquid when it reaches the desired level.
-
-
Mounting Options:
The sensor can be affixed to the wall of a tank or system using mounting brackets, adhesive (if applicable), or it can be clamped in place. -
Distance from Liquid:
The sensor should be mounted such that the sensor tip is within the sensing range (typically 0.5 cm to 5 cm) from the liquid's surface to enable accurate detection.
2. Wiring the Sensor:
-
Power Supply:
Connect the sensor to a DC power supply that provides a voltage between 6V and 36V.-
Red wire (VCC): Connect to the positive terminal of the power supply.
-
Black wire (Ground): Connect to the negative terminal of the power supply.
-
-
Output Signal:
The black wire (output) is the NPN sinking signal. It will be connected to your controller (e.g., PLC, relay, or a switching system).-
When the liquid level is detected, the sensor's output will switch to ground (active low). This can be used to trigger actions like activating alarms, controlling pumps, or starting a filling process.
-
-
Signal Testing:
Once powered up, the sensor will immediately detect the liquid presence or absence and provide an output signal based on the liquid level.
3. Calibration and Sensitivity Adjustment:
-
Some models may come with sensitivity adjustment settings. If available, you can fine-tune the detection distance or threshold to match your system's requirements.
-
If the sensor does not detect the liquid or produces inconsistent outputs, check the installation and ensure it is within the liquid's sensing range.
4. Testing the Sensor:
-
After installation, test the system by adding or removing liquid from the tank. The sensor should trigger its output when the liquid level changes and enters the defined sensing range.
-
Example Application:
For a high-level liquid alarm, mount the sensor at the desired maximum liquid level. As the liquid reaches this level, the sensor will output a signal, which can trigger an alarm or shut off a pump.
Applications of the XKC-Y25-NPN Non-Contact Liquid Level Sensor:
-
Water Tank Monitoring:
Use the sensor to detect high or low water levels in tanks or reservoirs, ensuring proper water supply or preventing overflows. -
Liquid Overflow Prevention:
In industrial applications, it helps to prevent liquid spills or overflows by detecting liquid levels in tanks and activating pumps or shut-off valves when needed. -
Dry-Run Protection in Pumps:
This sensor can prevent dry running of pumps by detecting when the liquid falls below the safe operating level, thus avoiding damage to the pump motor. -
Aquarium Systems:
The sensor is useful in aquarium setups where it can help in maintaining consistent water levels and preventing water overflow. -
Agricultural Irrigation Systems:
The sensor can be used to monitor water levels in irrigation tanks or reservoirs, ensuring the system operates effectively without dry-run issues. -
Fluid Storage Systems:
The sensor helps monitor liquid levels in storage tanks for industrial fluids, chemicals, or fuels, triggering necessary actions based on the liquid's height. -
Cooling Systems:
In cooling towers or coolant reservoirs, it can detect liquid levels, ensuring the system stays within operational parameters.
Advantages of the XKC-Y25-NPN Non-Contact Liquid Level Sensor:
-
Non-Contact Operation:
The sensor detects the liquid level without any direct contact, preventing contamination and mechanical wear on the sensor. -
Precise Detection:
With a sensitivity range of 0.5 cm to 5 cm, it allows for accurate level monitoring in various tanks, containers, or reservoirs. -
Long-lasting and Durable:
The IP67 rating makes it dust-tight and waterproof, ensuring reliable performance even in outdoor or harsh environments. -
Wide Voltage Range:
The 6V to 36V DC operating voltage range allows the sensor to be used in a wide variety of systems and control circuits. -
Fast Response Time:
The sensor’s quick response time (< 10 ms) allows for real-time feedback, making it ideal for fast-paced or automated applications. -
Compact Design: