Product Page
AC servo Panasonic Xinje DSCK-20P4–PTA DS5L-21P5-AS2 AE Servo Delta
₨0
Need some help?
Contact Us
Product Ships in
2-3-business Days
Payment Methods:
AC servo Panasonic Xinje DSCK-20P4--PTA DS5L-21P5-AS2 AE Servo Delta in Lahore Pakistan
Here’s a detailed breakdown for your website content regarding these AC Servo products:
1. Xinje DS5L‑20P4‑PTA Servo Driver (Pulse Type)
Overview & Key Specs
-
Series: DS5L pulse-type servo driver
-
Power Range: 0.1 kW to 2.6 kW—specifically the “20P4” denotes ~0.4 kW, and “21P5” denotes 1.5 kW en.xinje.com.
-
Input Voltage: Single or three-phase AC 200–240 V or 340–420 V 50/60 Hz en.xinje.com.
-
Encoder Feedback: 17-bit or 23-bit communication encoder, designated by “PTA” encoding in model naming en.xinje.com.
-
Control Modes: Seamless switching among position, speed, and torque control en.xinje.com.
I/O & Connectivity
-
Digital Inputs (DI): 3 for ≤750 W variants; 4 for higher power models en.xinje.com.
-
Digital Outputs (DO): Similarly, 3 or 4 depending on power range en.xinje.com.
-
Input Modes Supported: Pulse + direction, AB phase pulse, CW/CCW signals; max input frequency ~200 kpps (open collector) en.xinje.com.
-
Communication: RS‑232 MODBUS-RTU interface, for integration with PLCs or configuration tools en.xinje.com.
Protection & Performance
-
Offers robust protection: over/under voltage, overcurrent, overheating, over-speed, encoder faults, short circuit, over-travel, oscillation, regeneration errors, overload, etc. en.xinje.com.
-
Regulation Performance:
-
Load Variation (0–100%): <±0.01% at rated speed
-
Voltage Variation (±10%): 0.01% at rated speed
-
Temperature Variation (±25 °C around 20 °C): <±0.1% at rated speed en.xinje.com.
-
Indicators & Controls
-
Equipped with a 5-digit LED panel, power indicator, and 4 user buttons for manual diagnostics and tuning en.xinje.com.
2. Functions & “Future” Features
Auto-Tuning & Adaptive Control
-
Adaptive Tuning: The DS5 series supports internal/external instruction auto-tuning, estimating inertia and adapting gain automatically for faster setup and optimized performance ManualsLib+1.
-
Operating Modes:
-
External Command Self‑Tuning: Commanded by upper-level motion control
-
Internal Command Self‑Tuning: Driver adjusts based on its own detected mechanical/environmental feedback ManualsLib+1.
-
-
Manual/Quick Adjustment: Users can manually tweak gain, speed, vibration suppression, based on rigidity requirements—high responsiveness vs low noise etc. ManualsLib+1.
Auto‑Tuning Workflow (Quick Summary)
-
Mount driver and motor; ensure correct wiring (U, V, W phases, ground, etc.) ManualsLib.
-
Power on; use panel to trigger F0‑07 (inertia ID) or F0‑09/F0‑10 (self‑tuning commands) ManualsLib+1.
-
Panel displays status; press ENTER to commence tuning, driver automatically fine‑tunes based on mechanism type and load inertia ManualsLib+1.
-
Final adjustments can be made manually if needed (e.g., P2‑16, rigidity coefficient) ManualsLib+1.
Why It Matters (“Futures”)
-
Ease of Setup: Reduces trial-and-error wiring/tuning, speeds commissioning.
-
Flexibility: Adaptable to various systems—belt-driven, screw-driven, direct coupling.
-
Stability & Precision: Auto-tuned parameters improve accuracy and reduce vibration.
-
Advanced Diagnostics: Built-in panel feedback and servo alarms allow quick fault identification and maintenance.
3. How to Use (Step‑by‑Step)
-
Hardware Setup
-
Power Connection: Match driver voltage rating (220 V or 380 V), connect main power, ground reliably to heat sink. ManualsLib
-
Motor Wiring: Connect motor leads U, V, W; ensure proper motor-driver phase alignment to avoid locking. ManualsLib
-
Encoder Cable: Connect CN2 for communication encoder.
-
DI/DO Signals: Wire inputs such as servo-enable, direction, mode; outputs for alarms, ready signals, etc. ManualsLib
-
Brake Resistor: Use built-in resistor; add external resistor if above threshold (e.g., models ≥500 W may need 40 Ω to 100 Ω) ManualsLib.
-
-
Initial Setup & Connectivity
-
Use panel or PC tool (e.g. Xinje Servo Tuner via RS‑232) for configuration. PLCHMI Unlock
-
Set communication settings: e.g., baud rate 19,200 bps, 8‑bit data, 1 stop bit, even parity by default ManualsLib.
-
-
Auto‑Tuning & Calibration
-
Run inertia estimation (F0‑07) and auto‑tuning (F0‑09 internal, or external command).
-
Review and, if needed, manually refine parameters like rigidity, vibration suppression, loop gains. ManualsLib
-
-
Operation & Monitoring
-
Send motion commands via pulses or analog inputs; monitor LEDs and fault outputs.
-
Watch for servo ready, positioning complete signals, alarms, torque limits, and other diagnostics. en.xinje.comManualsLib
-
-
Maintenance & Troubleshooting
-
Use alarm list and panel diagnostics to identify issues (e.g., ERR–1 = torque saturation).
-
Perform zero-current sampling, encoder battery checks, and inertia re-estimation as needed for stable long‑term use. ManualsLib
-
Summary Table
| Feature | Details |
|---|---|
| Model | DS5L‑20P4‑PTA (0.4 kW), DS5L‑21P5‑PTA (1.5 kW) |
| Control Modes | Position, Speed, Torque — seamless switching |
| I/O Interface | Pulse, AB, CW/CCW; 3–4 DI/DO; encoder; RS‑232/MODBUS |
| Auto‑Tuning | Internal/external inertia estimation + gain tuning |
| Protection | Comprehensive fault handling (overvoltage, overload, encoder error, etc.) |
| Indicators | 5‑digit LED display + multi-purpose buttons for setup & diagnostics |
| Usage Workflow | Wiring → Configure → Auto‑Tune → Operate → Monitor & Maintain |