Product Page

AC servo Panasonic Xinje DSCK-20P4–PTA DS5L-21P5-AS2 AE Servo Delta

0

Need some help?

Contact Us

Product Ships in

2-3-business Days

Payment Methods:

AC servo Panasonic Xinje DSCK-20P4--PTA DS5L-21P5-AS2 AE Servo Delta in Lahore Pakistan

Here’s a detailed breakdown for your website content regarding these AC Servo products:


1. Xinje DS5L‑20P4‑PTA Servo Driver (Pulse Type)

Overview & Key Specs

  • Series: DS5L pulse-type servo driver

  • Power Range: 0.1 kW to 2.6 kW—specifically the “20P4” denotes ~0.4 kW, and “21P5” denotes 1.5 kW en.xinje.com.

  • Input Voltage: Single or three-phase AC 200–240 V or 340–420 V 50/60 Hz en.xinje.com.

  • Encoder Feedback: 17-bit or 23-bit communication encoder, designated by “PTA” encoding in model naming en.xinje.com.

  • Control Modes: Seamless switching among position, speed, and torque control en.xinje.com.

I/O & Connectivity

  • Digital Inputs (DI): 3 for ≤750 W variants; 4 for higher power models en.xinje.com.

  • Digital Outputs (DO): Similarly, 3 or 4 depending on power range en.xinje.com.

  • Input Modes Supported: Pulse + direction, AB phase pulse, CW/CCW signals; max input frequency ~200 kpps (open collector) en.xinje.com.

  • Communication: RS‑232 MODBUS-RTU interface, for integration with PLCs or configuration tools en.xinje.com.

Protection & Performance

  • Offers robust protection: over/under voltage, overcurrent, overheating, over-speed, encoder faults, short circuit, over-travel, oscillation, regeneration errors, overload, etc. en.xinje.com.

  • Regulation Performance:

    • Load Variation (0–100%): <±0.01% at rated speed

    • Voltage Variation (±10%): 0.01% at rated speed

    • Temperature Variation (±25 °C around 20 °C): <±0.1% at rated speed en.xinje.com.

Indicators & Controls

  • Equipped with a 5-digit LED panel, power indicator, and 4 user buttons for manual diagnostics and tuning en.xinje.com.


2. Functions & “Future” Features

Auto-Tuning & Adaptive Control

  • Adaptive Tuning: The DS5 series supports internal/external instruction auto-tuning, estimating inertia and adapting gain automatically for faster setup and optimized performance ManualsLib+1.

  • Operating Modes:

    • External Command Self‑Tuning: Commanded by upper-level motion control

    • Internal Command Self‑Tuning: Driver adjusts based on its own detected mechanical/environmental feedback ManualsLib+1.

  • Manual/Quick Adjustment: Users can manually tweak gain, speed, vibration suppression, based on rigidity requirements—high responsiveness vs low noise etc. ManualsLib+1.

Auto‑Tuning Workflow (Quick Summary)

  1. Mount driver and motor; ensure correct wiring (U, V, W phases, ground, etc.) ManualsLib.

  2. Power on; use panel to trigger F0‑07 (inertia ID) or F0‑09/F0‑10 (self‑tuning commands) ManualsLib+1.

  3. Panel displays status; press ENTER to commence tuning, driver automatically fine‑tunes based on mechanism type and load inertia ManualsLib+1.

  4. Final adjustments can be made manually if needed (e.g., P2‑16, rigidity coefficient) ManualsLib+1.

Why It Matters (“Futures”)

  • Ease of Setup: Reduces trial-and-error wiring/tuning, speeds commissioning.

  • Flexibility: Adaptable to various systems—belt-driven, screw-driven, direct coupling.

  • Stability & Precision: Auto-tuned parameters improve accuracy and reduce vibration.

  • Advanced Diagnostics: Built-in panel feedback and servo alarms allow quick fault identification and maintenance.


3. How to Use (Step‑by‑Step)

  1. Hardware Setup

    • Power Connection: Match driver voltage rating (220 V or 380 V), connect main power, ground reliably to heat sink. ManualsLib

    • Motor Wiring: Connect motor leads U, V, W; ensure proper motor-driver phase alignment to avoid locking. ManualsLib

    • Encoder Cable: Connect CN2 for communication encoder.

    • DI/DO Signals: Wire inputs such as servo-enable, direction, mode; outputs for alarms, ready signals, etc. ManualsLib

    • Brake Resistor: Use built-in resistor; add external resistor if above threshold (e.g., models ≥500 W may need 40 Ω to 100 Ω) ManualsLib.

  2. Initial Setup & Connectivity

    • Use panel or PC tool (e.g. Xinje Servo Tuner via RS‑232) for configuration. PLCHMI Unlock

    • Set communication settings: e.g., baud rate 19,200 bps, 8‑bit data, 1 stop bit, even parity by default ManualsLib.

  3. Auto‑Tuning & Calibration

    • Run inertia estimation (F0‑07) and auto‑tuning (F0‑09 internal, or external command).

    • Review and, if needed, manually refine parameters like rigidity, vibration suppression, loop gains. ManualsLib

  4. Operation & Monitoring

    • Send motion commands via pulses or analog inputs; monitor LEDs and fault outputs.

    • Watch for servo ready, positioning complete signals, alarms, torque limits, and other diagnostics. en.xinje.comManualsLib

  5. Maintenance & Troubleshooting

    • Use alarm list and panel diagnostics to identify issues (e.g., ERR–1 = torque saturation).

    • Perform zero-current sampling, encoder battery checks, and inertia re-estimation as needed for stable long‑term use. ManualsLib


Summary Table

Feature Details
Model DS5L‑20P4‑PTA (0.4 kW), DS5L‑21P5‑PTA (1.5 kW)
Control Modes Position, Speed, Torque — seamless switching
I/O Interface Pulse, AB, CW/CCW; 3–4 DI/DO; encoder; RS‑232/MODBUS
Auto‑Tuning Internal/external inertia estimation + gain tuning
Protection Comprehensive fault handling (overvoltage, overload, encoder error, etc.)
Indicators 5‑digit LED display + multi-purpose buttons for setup & diagnostics
Usage Workflow Wiring → Configure → Auto‑Tune → Operate → Monitor & Maintain